Home page of the 2011 BTF Calorimeter TB


Code repository

The code repository can be found here:

  • svn co svn+ssh://<youraccount>@pcaen1.ing2.uniroma1.it/home/sarti/SvnRepos/TestBeamCode/Btf_2011_Calo (template for motorola 5100)
  • svn co svn+ssh://<youraccount>@pcaen1.ing2.uniroma1.it/home/sarti/SvnRepos/TestBeamCode/Btf_2011_CaloBridge (template for bridged acq)
  • svn co svn+ssh://<youraccount>@pcaen1.ing2.uniroma1.it/home/sarti/SvnRepos/TestBeamCode/Btf_2011_CaloBridgeDecode (template for bridged acq decoding/analysis)

Hardware

Vista Top, plane 0 closest to the beam.

Schedule

  • Lunedi' : Installazione
  • Martedi': Debug acquisizione + run Panda
Obiettivi fondamentali:

DAQ

  • Crate sono direttamente alla Btf.

Software

DAQ

The acquisition software can be found in the top link at top of that page.

In order to run the acq you need to issue the command

  • acquire -n #evts -p #frequency check -f #filename
in order to stop it while running you need to type

  • touch acq.stop

Analizer

The software for the data processing is being developed. Latest version @ top of that page.

Configuration:

  • TDC: Chn 0-31 --> Chamber
  • TDC: Chn 32-33 --> Sipm
  • TDC: Chn 48,50 --> Calo, RF (trigger)
  • TDC: Chn 51,52 --> PMT's
  • QDC: 0, 2, 3, 4, 5 --> Calo, Sipm 1, 2, PMT 1, 2

Log Book

Trigger config:

Filename Config file HV condition thres Gas condition General Description Day Events
test_190411.dat conf_180411 2.0 kV Chmb, 15 mV. Sipm, 32 mV Ar CO2 90/10 Triggering on RF, high efficiency 19/04 11:00 "
RunTest_190411.dat " 2.0 kV " " " " 12:46 26k
Run_1_190411.dat conf_180411 " " " " " 17:00 23k
Run_2_190411.dat " " " " Adjusted Linear fan in/out. Now the 1st sipm appeared. Still need to recovery the second one. " 17:15 7k
Pedestal_2,3,4_190411.dat " " " " Trying to recover the second SIPM. Pedestal disappears. --> recovered in run 'pedestal_4' " 17:25 3k
Run_3_190411.dat " " " " First 'decent' run " 17:45  
Pedestal_Scint_190411.dat " " " " Pedestal run to see the newly added scintillators how are performing " 18:46  
Run_4_190411 " " " " Added two scintillators on the beam line to test the timing. Sipms are shutted down. "  
Run_5_190411 " " " " Turned on the Sipm! " 18:58  
Run_6_190411 " " " " Stessa configurazione " 19:20 10 k
Run_7_190411 " " " " Tolti scintillatori con PMTs posizione 3 Big con Sipm, posizione 3 small con Sipm " 19:55 10 k
Run_8_190411 " " " " posizione 1 Big con Sipm, posizione 1 Small con Sipm " 20:15 10 k
Run_9_190411 " " " " posizione 5 Big con Sipm, posizione 5 Small con Sipm " 20:35 10 k
Run_10_190411 " " " " stessa posizione per aumentare la statistica. Fascio si e' spento a meta' del file " 20:40 10 k
Run_11_190411 " " " " stessa posizione " 20:55 10 k
Run_12_190411 " " " " posizione 4 Big con Sipm, posizione 4 Small con Sipm " 21:15 10 k
Run_13_190411 " " " " posizione 2 Big con Sipm, posizione 2 Small con Sipm. Interrotto a causa del cambio in e " 21:30 8.5 k
Run_14_190411 " " " " posizione 6 Big con Sipm, posizione 2 Small con Sipm " 22:00 10 k
Run_Sipm_0_200411 conf_180411 " Chmb, 15 mV. Sipm, 42 mV, PM 20 mV " Sipm e PM in posizione 1. (Small) 20/04 11:20  
Run_32_200411 " " " " " 13:00 10k
Run_33_200411 " " " " " " 20k
Run_34_200411 " " " " Sipm e PM in posizione 3 (Small) Run-lungo 13:15 100k
Run_35_200411 " " " " Sipm e PM in posizione 5 (Small) 14:40 40k
Run_36_200411 " " " " " fascio un po' sporco 15:40 9k
Run_37_200411 " " " " Sipm e PM in posizione 4 (Small) - switch e+/e- poca statistica (da riprendere) 16:05 30k
Run_38_200411 " " Chmb, 15 mV. Sipm, 10 mV, PM 20 mV "

Sipm e PM in posizione 2 (Small) switch e-/e+

poca statistica (da riprendere)

16:46 20k
Run_39_200411 " " " " " 17:05 20k
Run_40_200411 " " " " " 17:31 9k
Run_41_200411 " " " " " Soglia fissata a 30 mV run di prova 17:56 2.2k
Run_42_200411 " " Chmb, 15 mV. Sipm, 30 mV, PM 20 mV " " 18:10 20k
Run_43_200411 " " " " Sipm in posizione 4 19:00 20 k
Run_44_200411 " " " " Big Sipm in posizione 5; Big PMT in posizione 5 19:35 20 k
Run_45_200411 " " " " Big Sipm in posizione 3; Big PMT in posizione 3. Interrotto per switch e+ to e- 20:05 20 k
Run_46_200411 " " " " " 20:15 20 k
Run_47_200411 " " " " Big Sipm in posizione 1; Big PMT in posizione 1. Due cambi di fascio nel file 20:35 20 k
Run_48_200411 " " " " " 20:55 5 k
Run_49_200411 " " " " Big Sipm in posizione 6; Big PMT in posizione 6 21:05 20 k
Run_50_200411 " " " " Big Sipm in posizione 4; Big PMT in posizione 4; cambio fascio e+ to e- a 18000 eventi 21:35 20 k
Run_51_200411 " " " " " 21:50 5 k
Run_52_200411 " " " " Big Sipm in posizione 2; Big PMT in posizione 2 22:00 20 k
Run_53_200411 " " Chmb 15mV " No scintillatori. Set-up alla PANDA 22:30  
Run_57_210411 " "

Chmb 15 mV,

SipmI: 29.6 V 28.9 mV

SipmII: 30.5 V 28.9 mV

" Sipm I e Sipm II per scan in soglia e tensione di alimentazione 12:00 11.6k
Run_58_210411 " "

Chmb 15 mV,

SipmI:29.6 V 20 mV

SipmII:30.5 V 20 mV

" " 12:20 9.7k
Run_59_210411 " "

Chmb 15 mV,

SipmI: 29.6 V 10 mV

SipmII: 30.5 V 10 mV

" " 12:35 9.9k
Run_60_210411 " "

Chmb 15 mV,

SipmI: 30.1 V 30 mV

SipmII: 31 V 30 mV

" " 12:55 10k
Run_61_210411 " "

Chmb 15 mV,

SipmI: 30.1 V 30 mV

SipmII: 31 V 30 mV

" Cavo Sipm srotolato (rumore @ 15kHz sembra indipendente dal guadagno) 13:10 10k
Run_62_210411 " "

Chmb 15 mV,

SipmI: 30.1 V 20 mV

SipmII: 31 V 20 mV

" " 13:30  
               

Eventi

  • 18/04: installato il tutto
  • 19/04 mattina: arrivano gli scintillatori e si riesce finalmente a far partire l'acquisizione.
  • 19/04 : Ore 17. Dopo aver sostituito il crate nim, finalmente vediamo i tempi della camera e della RF
  • 19/04 : Ore 18:30 big con Sipm=posizione 3; Small con Sipm=posizione 3; Big con PMT=posizione 3; Small con PMT=posizione a caso.
  • 19/04 : Ore 19:40 tolti gli scintillatori con PMTs; iniziato lo scan in posizione
  • 19/04 : Ore 22:20 stop scan in posizione scintillatori. Durante la notte cameretta a 2 kV e pallino ai panda. Si spera di fare T0 e ST relations
  • 20/04 : Ore 11:20. Rimesso in posizione Small Sipm e Fotomoltiplicatori. Camera ancora a 2. kV. Soglie SIPM @ 42 mV, Soglie PM @ 20 mV.
  • 20/04: Ore 16:40. Cambio soglie Sipm da 42 mV a 10 mV (il valore di tensione letto sulla scheda va diviso per un fattore 4.5)
  • 20/04: Ore 17:40. Cambio soglie Sipm da 10 mV a 30 mV (segnale affogato dal rumore)
  • 20/04: Ore 19:35. Inizio scan in posizione Big Sipm e PMT. Soglia Sipm=30 mV
  • 20/04: Ore 22:30. Rimossi scintillatori. Set-up PANDA
  • 21/04: Ore 11:00. Si parte con lo scan in soglia e guadagno dei Sipm
-- AlessioSarti - 2011-04-13
Edit | Attach | Watch | Print version | History: r17 | r15 < r14 < r13 < r12 | Backlinks | Raw View | Raw edit | More topic actions...
Topic revision: r13 - 2011-04-21 - AlessioSarti
 
  • Edit
  • Attach
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2024 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback